Acteon Minimal Excavation and Micro-Abrasion

In stock
SKU
exctips
Grouped product items
Product Name Qty Price
Tip No. EX1, Ref: F02040 Full Ball
£84.61 £101.53
Tip No. EX2, Ref: F02041 Mesial 1/2 Ball
£84.61 £101.53
Tip No. EX3, Ref: F02042 Distal 1/2 Ball
£84.61 £101.53
Tip No. EXR, Ref: F02043 Right-Oriented 1/2 Ball
£82.95 £99.54
Tip No. EXL, Ref: F02044 Left-Oriented 1/2 Ball
£82.95 £99.54
Acteon Excavus Kit - EX1, EX2, EX3, EXL, EXR tips plus holder & wrench
£419.83 £503.80

 Acteon Tip No EX1

 

 Acteon Scaling Tip No ex1

F02040 No EX1: Diamond-coated full ball tip 46μm.

Preparation of the occlusal surface and cervical margins.

Removal of hyper-mineralised dental structure.

 

 Acteon Tip No EX2

 

 Acteon Tip No EX2

F02041 No. EX2: Diamond-coated, mesial 1/2 ball tip 46μm.

Preparation of the mesial surface wihout lesions on the adjacent tooth surface.

 Acteon Tip No EX3

 

 Acteon Tip No EX3

F02042 No. EX3: Diamond-coated, distal 1/2 ball tip 46μm.

Preparation of the distal surface without lesions on the adjacent tooth surface.

 Acteon Tip No EXR  Acteon Tip No 10x

F02043 No. EXR: Diamond-coated, right-oriented 1/2 ball tip 46μm.

Curved 45° to the right, the EXR tip allows access to the lesion, particularly in posterior areas, without damaging adjacent teeth.

 Acteon Tip No EXL

 

 Acteon Tip No EXL

F02044 No. EXL: Diamond-coated, left-oriented 1/2 ball tip 46μm.

Curved 45° to the left, the EXL tip allows access to the lesion, particularly in posterior areas, without damaging adjacent teeth.

Excavus tips provide excellent abrasion quality due to the regularity of their diamond coating.

Preserve Teeth With Perfect Ultrasonic Vibrations and Steel Tip Quality

Acteon® equipment technologies and tips responds to practitioners clinical expertise.

The ultrasonic micro-oscillations transmitted from the handpiece to the tip generate perfectly linear movement. Therefore the tip undergoes to-and-fro movements in the axis of the handpiece.

The active area of each tip is located on the distal 2-3mm. This working section may be applied on the surface to be treated, moving progressively from the crown to the root.

Linear Movement

The linear movement of the tip can be used in various ways which are also complimentary:

Sweeping: indicated for scaling and disrupting the biofilm.

The tip must be applied tangentially on the part to be treated, and used over its entire active section.

Hammering: used to fragment large tartar deposits and remove cements.

The tip must be positioned facing the element to be detached, and used without pressure on its point.

Newtron® Technology

The unmatched performance of Newtron® technology paves the way for more precise, faster and painless procedures.

Oscillations

The frequency (number of oscillations per second) of each tip adjusts in real time:

  • Better tactile sense
  • No power loss
  • Soft tissue preservation

Amplitude 

The amplitude (tip movement) is perfectly controlled and constant:

  • Very regular sweeping effect
  • Gentle vibrations giving a pain-free treatment

Power 

The power required is instantly adjusted depending on the resistance encountered by the tip:

  • No pressure necessary
  • Decrease fatigue for the practitioner
  • Greater efficiency

Cavitation

The ultrasonic vibrations also cause a biological effect called cavitation, which has interesting benefits.

When a liquid is exposed to ultrasonic vibrations, the acoustic wave induces quite large pressure changes to create small bubbles of vapor called cavitation.

These bubbles are extremely unstable and burst violently, leading to the fragmentation and removal of the deposits.

In addition cavitation creates micro-bubbles of oxygen which have a cleansing, disinfectant effect.

Write Your Own Review
You're reviewing:Acteon Minimal Excavation and Micro-Abrasion
Your Rating