PenguinRFA Osseointegration Monitor

In stock
Only 0 left
SKU
PRFA1
£1,450.00 £1,740.00

 

PenguinRFA - Removes Doubt

In today's implant dentistry, the trend is to use short or no healing periods before loading. This places high demands on the clinical team. If conditions are not optimal, poor primary stability may increase the risk of implant failure. PenguinRFA provides accurate and objective measurements of implant stability, serving as a reliable support when making decisions when to load.

 

Monitor Osseointegration

  • Reduce treatment time
  • Manage risk patients

 

Removes Doubt

PenguinRFA measures implant stability and osseointegration to enhance decisions about when to load. Especially important when using protocols with shorter treatment time or treating risk patients.

 

Objective and Non-Invasive Operation

PenguinRFA measures the resonance frequency of the reusable MulTipegTM with a non-contacting technique. The frequency is displayed as an ISQ-value (Implant Stability Quotient) from 1-99. The ISQ value correlates strongly to the micro mobility of the implant.

 

Optimised Patient Care - Now In The Palm of Your Hand

Just mount the MulTipegTM, aim for the top and the ISQ value will be displayed in less than a second. Values above 70 means high stability and are typically used for one-stage and immediate loading.

By taking a baseline value at implant placement and another before loading, the degree of osseointegration can be measured.

 

What Do I Need?

To get started, you need the PenguinRFA Starter Kit and the appropriate MulTipegsTM from our MulTipegTM Assortment.

Our reusable MulTipegsTM are available for a wide range of implant systems. They are durable and tissue friendly, and fully autoclavable. Can't see the MuliTipegTM you were looking for? Give us a bell on 01535 656312.

 

The RFA Technique

Penguin RFA

 

 

Resonance Frequency Analysis (RFA) was introduced in implant dentistry more than 20 years ago. A peg attached to an implant is excited and the vibration frequency is picked up by the instrument and presented as an ISQ (Implant Stability Quotient) value.

PenguinRFA measures the resonance frequency of the MulTipegTM, which depends on the stability of the implant.

The measurement scale is from 1 to 99 ISQ. The ISQ value correlates strongly to the micro mobility of the implant, which in turn depends on bone quality and osseointegration. A more detailed scientific descriptiopn can be found at PenguinRFA.com.

More than 700 articles on the subject have been published in peer-reviewed papers since 1996. You can see references to a selection of the most-important ones here. We especially recommend the summarising article by Prof. Lars Sennerby, which explains the RFA-technique, the ISQ-Scale and how to use PenguinRFA clinically.

 

No Hassle:

Reusable MulTipegsTM. Uncomplicated and affordable.

MulTipegTM (titanium)
  • Reusable
  • Autoclavable
  • Calibrated
Penguin MulTipeg

MulTipegTM Driver

  • Reusable
  • Autoclavable
  • Stainless Steel
Penguin MulTipeg Driver

PenguinRFA Instrument

  • Handheld
  • Rechargeable
  • Accurate

Penguin RFA

 

 

 

 

 

 

The Original Team:

PenguinRFA is the result of more than twenty years' research and development by a small, dedicated scientific team.

Their experience and close relationship with specialists across the world has been instrumental in creating the PenguinRFA concept.

The projects' defining ambition has been to offer an uncomplitcated and affordable concept for all clinicians working with implants.

Prof Lars Sennerby

Lars Sennerby, Prof, DDS

Prof Sennerby is a leading authority within clinical implant dentistry. He has had more than 250 articles published and has lectured extensively across the world. Lars has been a pioneer in the clinical development of RFA since 1996, and has used the technique since then.

Anders Petersson

Anders Petersson, President

Anders started the company Osstell in 1999, together with the inventors of RFA, Prof Neil Meredith and Prof Peter Cawley. Anders developed the RFA technique from its’ early prototypes to a commercial product in 2001 and was later responsible for the development of the contactless technique for measuring. Anders has been in the dental implant industry since 1993.